The use of thermal manikin to evaluate interface pressure distribution |
| |
Authors: | Ciaccia Flavia Renata Dantas Alves Silva Gonçalves Clenilson Jordão Sznelwar Laerte Idal |
| |
Affiliation: | Department of Production Engineering, School ofEngineering-University of S?o Paulo, Avenida Prof. AlmeidaPrado, Cidade Universitária - S?o Paulo/SP, Brazil. fla_silva@hotmail.com |
| |
Abstract: | ![]() The use of a thermal buttocks manikin was explored as a tool to standardize the evaluation of seat comfort. Thermal manikin buttocks were developed and calibrated thermally and anatomically to simulate the sensible heat transfer of a seated person and used to evaluate interface pressure distribution. In essence, the pressure maps of manikin buttocks with and without heating were compared to those of a seated person. The results of average pressure demonstrated that the thermal manikins have a better response in interface pressure measurement than manikins without heating. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|