首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In practice, different practitioners will use different Phase I samples to estimate the process parameters, which will lead to different Phase II control chart's performance. Researches refer to this variability as between-practitioners-variability of control charts. Since between-practitioners-variability is important in the design of the CUSUM median chart with estimated process parameters, the standard deviation of average run length (SDARL) will be used to study its properties. It is shown that the CUSUM median chart requires a larger amount of Phase I samples to sufficiently reduce the variation in the in-control ARL of the CUSUM median chart. Considering the limitation of the amount of the Phase I samples, a bootstrap approach is also used here to adjust the control limits of the CUSUM median chart. Comparisons are made for the CUSUM and Shewhart median charts with estimated parameters when using the adjusted- and unadjusted control limits and some conclusions are made.  相似文献   

2.
In this paper, we study the effect of estimating the vector of means and the variance–covariance matrix on the performance of two of the most widely used multivariate cumulative sum (CUSUM) control charts, the MCUSUM chart proposed by Crosier [Multivariate generalizations of cumulative sum quality-control schemes, Technometrics 30 (1988), pp. 291–303] and the MC1 chart proposed by Pignatiello and Runger [Comparisons of multivariate CUSUM charts, J. Qual. Technol. 22 (1990), pp. 173–186]. Using simulation, we investigate and compare the in-control and out-of-control performances of the competing charts in terms of the average run length measure. The in-control and out-of-control performances of the competing charts deteriorate significantly if the estimated parameters are used with control limits intended for known parameters, especially when only a few Phase I samples are used to estimate the parameters. We recommend the use of the MC1 chart over that of the MCUSUM chart if the parameters are estimated from a small number of Phase I samples.  相似文献   

3.
The Shewhart p-chart or np-chart is commonly used for monitoring the counts of non-conforming items which are usually well modelled by a binomial distribution with parameters n and p where n is the number of items inspected each time and p is the process fraction of non-conforming items produced. It is well known that the Shewhart chart is not sensitive to small shifts in p. The cumulative sum (CUSUM) chart is a far more powerful charting procedure for detecting small shifts in p and only marginally less powerful in detecting large shifts in p. The choice of chart parameters of a Shewhart chart is well documented in the quality control literature. On the other hand, very little has been done for the more powerful CUSUM chart, possibly due to the fact that the run length distribution of a CUSUM chart is much harder to compute. An optimal design strategy is given here which allows the chart parameters of an optimal CUSUM chart to be determined easily. Optimal choice of n and the relationship between the CUSUM chart and the sequential probability ratio test are also investigated.  相似文献   

4.
The memory-type control charts are widely used in the process and service industries for monitoring the production processes. The reason is their sensitivity to quickly react against the small process disturbances. Recently, a new cumulative sum (CUSUM) chart has been proposed that uses the exponentially weighted moving average (EWMA) statistic, called the EWMA–CUSUM chart. Similarly, in order to further enhance the sensitivity of the EWMA–CUSUM chart, we propose a new CUSUM chart using the generally weighted moving average (GWMA) statistic, called the GWMA–CUSUM chart, for efficiently monitoring the process mean. The GWMA–CUSUM chart encompasses the existing CUSUM and EWMA–CUSUM charts. Extensive Monte Carlo simulations are used to explore the run length profiles of the GWMA–CUSUM chart. Based on comprehensive run length comparisons, it turns out that the GWMA–CUSUM chart performs substantially better than the CUSUM, EWMA, GWMA, and EWMA–CUSUM charts when detecting small shifts in the process mean. An illustrative example is also presented to explain the implementation and working of the EWMA–CUSUM and GWMA–CUSUM charts.  相似文献   

5.
6.
The run sum chart is an effective two-sided chart that can be used to monitor for process changes. It is known that it is more sensible than the Shewhart chart with runs rules and its performance improves as the number of regions increases. However, as the number of regions increses the resulting chart has more parameters to be defined and its design becomes more involved. In this article, we introduce a one-parameter run sum chart. This chart accumulates scores equal to the subgroup means and signals when the cummulative sum exceeds a limit value. A fast initial response feature is proposed and its run length distribution function is found by a set of recursive relations. We compare this chart with other charts suggested in the literature and find it competitive with the CUSUM, the FIR CUSUM, and the combined Shewhart FIR CUSUM schemes.  相似文献   

7.
Frequently in process monitoring, situations arise in which the order that events occur cannot be distinguished, motivating the need to accommodate multiple observations occurring at the same time, or concurrent observations. The risk-adjusted Bernoulli cumulative sum (CUSUM) control chart can be used to monitor the rate of an adverse event by fitting a risk-adjustment model, followed by a likelihood ratio-based scoring method that produces a statistic that can be monitored. In our paper, we develop a risk-adjusted Bernoulli CUSUM control chart for concurrent observations. Furthermore, we adopt a novel approach that uses a combined mixture model and kernel density estimation approach in order to perform risk-adjustment with regard to spatial location. Our proposed method allows for monitoring binary outcomes through time with multiple observations at each time point, where the chart is spatially adjusted for each Bernoulli observation's estimated probability of the adverse event. A simulation study is presented to assess the performance of the proposed monitoring scheme. We apply our method using data from Wayne County, Michigan between 2005 and 2014 to monitor the rate of foreclosure as a percentage of all housing transactions.  相似文献   

8.
A statistical quality control chart is an important tool of the statistical process control, which is widely used to control and monitor a production process. The CUSUM chart is designed to detect a specific shift, provided that the shift size is known in advance. In practice, however, shift sizes are rarely known. It is then customary to use an adaptive CUSUM chart, which can effectively detect a range of shift sizes. In this paper, we enhance the sensitivities of the improved adaptive CUSUM mean charts using an auxiliary-information-based (AIB) mean estimator. The run length performances of the proposed charts are compared with those of the AIB adaptive and non-adaptive CUSUM charts in terms of the average run length (ARL), extra quadratic loss, and integral relative ARL. These run length comparisons reveal that the proposed charts are more sensitive than the existing charts when detecting different kinds of shift in the process mean. An example is given to demonstrate the implementation of existing and proposed charts.  相似文献   

9.
The performance of the cumulative sum (CUSUM) control chart for the mean when measurement error exists is investigated. It is shown that the CUSUM chart is greatly affected by the measurement error. A similar result holds for the case of the CUSUM chart for the mean with linearly increasing variance. In this paper, we consider multiple measurements to reduce the effect of measurement error on the charts performance. Finally, a comparison of the CUSUM and EWMA charts is presented and certain recommendations are given.  相似文献   

10.
In this paper we discuss the behavior of the Shewhart residual chart and the modified Shewhart chart if the parameters of the underlying process are unknown and thus have to be estimated. We focus on the estimation of the variance. For AR models we also consider the estimation of the AR coefficients. The average run length (ARL) of the control chart with estimated parameters is compared with the ARL of the scheme for known parameters and with the ARL for independent variables. Additionally, we give recommendations on the choice of the estimators in the context of Shewhart control schemes.  相似文献   

11.
This article analyses and evaluates the properties of a CUSUM chart designed for monitoring the process mean in short production runs. Several statistical measures of performance that are appropriate when the process operates for a finite-time horizon are proposed. The methodology developed in this article can be used to evaluate the performance of the CUSUM scheme for any given set of chart parameters from both an economic and a statistical point of view, and thus, allows comparisons with various other charts.  相似文献   

12.
Control chart is an important statistical technique that is used to monitor the quality of a process. Shewhart control charts are used to detect larger disturbances in the process parameters, whereas cumulative sum (CUSUM) and exponential weighted moving average (EWMA) are meant for smaller and moderate changes. In this study, we enhanced mixed EWMA–CUSUM control charts with varying fast initial response (FIR) features and also with a runs rule of two out of three successive points that fall above the upper control limit. We investigate their run-length properties. The proposed control charting schemes are compared with the existing counterparts including classical CUSUM, classical EWMA, FIR CUSUM, FIR EWMA, mixed EWMA–CUSUM, 2/3 modified EWMA, and 2/3 CUSUM control charting schemes. A case study is presented for practical considerations using a real data set.  相似文献   

13.
This study examines the statistical process control chart used to detect a parameter shift with Poisson integer-valued GARCH (INGARCH) models and zero-inflated Poisson INGARCH models. INGARCH models have a conditional mean structure similar to GARCH models and are well known to be appropriate to analyzing count data that feature overdispersion. Special attention is paid in this study to conditional and general likelihood ratio-based (CLR and GLR) CUSUM charts and the score function-based CUSUM (SFCUSUM) chart. The performance of each of the proposed methods is evaluated through a simulation study, by calculating their average run length. Our findings show that the proposed methods perform adequately, and that the CLR chart outperforms the GLR chart when there is an increased shift of parameters. Moreover, the use of the SFCUSUM chart in particular is found to lead to a lower false alarm rate than the use of the CLR chart.  相似文献   

14.
The adaptive memory-type control charts, including the adaptive exponentially weighted moving average (EWMA) and cumulative sum (CUSUM) charts, have gained considerable attention because of their excellent speed in providing overall good detection over a range of mean shift sizes. In this paper, we propose a new adaptive EWMA (AEWMA) chart using the auxiliary information for efficiently monitoring the infrequent changes in the process mean. The idea is to first estimate the unknown process mean shift using an auxiliary information based mean estimator, and then adaptively update the smoothing constant of the EWMA chart. Using extensive Monte Carlo simulations, the run length profiles of the AEWMA chart are computed and explored. The AEWMA chart is compared with the existing control charts, including the classical EWMA, CUSUM, synthetic EWMA and synthetic CUSUM charts, in terms of the run length characteristics. It turns out that the AEWMA chart performs uniformly better than these control charts when detecting a range of mean shift sizes. An illustrative example is also presented to demonstrate the working and implementation of the proposed and existing control charts.  相似文献   

15.
The Zero-inflated Poisson distribution (ZIP) is used to model the defects in processes with a large number of zeros. We propose a control charting procedure using a combination of two cumulative sum (CUSUM) charts to detect increases in the parameters of ZIP process, one is a conforming run length (CRL) CUSUM chart and another is a zero truncated Poisson (ZTP) CUSUM chart. The control limits of the control charts are obtained using both Markov chain-based methods and simulations. Simulation experiments show that the proposed method outperforms an existing method. Finally, a real example is presented.  相似文献   

16.
CUSUM control schemes for Gaussian processes   总被引:1,自引:1,他引:0  
A CUSUM control scheme for detecting a change point in a Gaussian process is derived. An upper and a lower bound for the distribution of the run length and for its moments is given. In a Monte Carlo study the average run length (ARL) of this chart is compared with the ARL of two other CUSUM procedures which are based on approximations to the sequential probability ratio, and, moreover, with EWMA schemes for autocorrelated data. Results on the optimal choice of the reference value are presented. Furthermore it is investigated how these charts behave if the model parameters are estimated.  相似文献   

17.
The Weibull distribution is one of the most popular distributions for lifetime modeling. However, there has not been much research on control charts for a Weibull distribution. Shewhart control is known to be inefficient to detect a small shift in the process, while exponentially weighted moving average (EWMA) and cumulative sum control chart (CUSUM) charts have the ability to detect small changes in the process. To enhance the performance of a control chart for a Weibull distribution, we introduce a new control chart based on hybrid EWMA and CUSUM statistic, called the HEWMA-CUSUM chart. The performance of the proposed chart is compared with the existing chart in terms of the average run length (ARL). The proposed chart is found to be more sensitive than the existing chart in ARL. A simulation study is provided for illustration purposes. A real data is also applied to the proposed chart for practical use.  相似文献   

18.
Traditional control charts assume independence of observations obtained from the monitored process. However, if the observations are autocorrelated, these charts often do not perform as intended by the design requirements. Recently, several control charts have been proposed to deal with autocorrelated observations. The residual chart, modified Shewhart chart, EWMAST chart, and ARMA chart are such charts widely used for monitoring the occurrence of assignable causes in a process when the process exhibits inherent autocorrelation. Besides autocorrelation, one other issue is the unknown values of true process parameters to be used in the control chart design, which are often estimated from a reference sample of in-control observations. Performances of the above-mentioned control charts for autocorrelated processes are significantly affected by the sample size used in a Phase I study to estimate the control chart parameters. In this study, we investigate the effect of Phase I sample size on the run length performance of these four charts for monitoring the changes in the mean of an autocorrelated process, namely an AR(1) process. A discussion of the practical implications of the results and suggestions on the sample size requirements for effective process monitoring are provided.  相似文献   

19.
ABSTRACT

We prove that the standard EWMA mean chart with asymptotic control limits and the EWMA mean chart with time-varying control limits for monitoring mean changes in a normal process with known mean and known variance are ARL-unbiased. Using the results derived we discuss the effects of estimation of the process mean on ARL.  相似文献   

20.
Many process characteristics follow an exponential distribution, and control charts based on such a distribution have attracted a lot of attention. However, traditional control limits may be not appropriate because of the lack of symmetry. In this paper, process monitoring through a normalizing power transformation is studied. The traditional individual measurement control charts can be used based on the transformed data. The properties of this control chart are investigated. A comparison with the chart when using probability limits is also carried out for cases of known and estimated parameters. Without losing much accuracy, even compared with the exact probability limits, the power transformation approach can easily be used to produce charts that can be interpreted when the normality assumption is valid.  相似文献   