首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Availability of a system subject to hidden failure inspected at constant intervals with non-negligible downtime due to inspection and downtime due to repair/replacement
Authors:Tianqiao Tang  Daming Lin  Dragan Banjevic  Andrew KS Jardine
Institution:Department of Mechanical and Industrial Engineering, University of Toronto, 5 King''s College Road, Toronto, Ontario, Canada M5S 3G8
Abstract:For systems with hidden or unrevealed failures, a common practice is to inspect the system regularly, since failures can only be detected upon inspection. Recent works in the literature have studied the availability of a system under periodic inspection, assuming perfect repair/replacement with non-negligible downtime due to repair/replacement for a detected failure. In some situations, however, not only downtime due to repair/replacement but also downtime due to inspection is non-negligible regardless whether a failure was detected or not. In this paper, we consider the availability of a system subject to hidden failure inspected at constant interval with both non-negligible downtime due to inspection and non-negligible downtime due to repair/replacement.
Keywords:Hidden failure  Instantaneous availability  Limiting average availability  Periodic inspection  Calendar-based  Age-based
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏