首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Receiver operating characteristic surfaces in the presence of verification bias
Authors:Yueh-Yun Chi  Xiao-Hua Zhou
Institution:University of Florida, Gainesville, USA;
University of Washington, Seattle, USA
Abstract:Summary.  In diagnostic medicine, the receiver operating characteristic (ROC) surface is one of the established tools for assessing the accuracy of a diagnostic test in discriminating three disease states, and the volume under the ROC surface has served as a summary index for diagnostic accuracy. In practice, the selection for definitive disease examination may be based on initial test measurements and induces verification bias in the assessment. We propose a non-parametric likelihood-based approach to construct the empirical ROC surface in the presence of differential verification, and to estimate the volume under the ROC surface. Estimators of the standard deviation are derived by both the Fisher information and the jackknife method, and their relative accuracy is evaluated in an extensive simulation study. The methodology is further extended to incorporate discrete baseline covariates in the selection process, and to compare the accuracy of a pair of diagnostic tests. We apply the proposed method to compare the diagnostic accuracy between mini-mental state examination and clinical evaluation of dementia, in discriminating between three disease states of Alzheimer's disease.
Keywords:Alzheimer's disease  Jackknife  Maximum likelihood estimate  Ordinal tests
设为首页 | 免责声明 | 关于勤云 | 加入收藏