首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A New Control Scheme Always Better Than X-Bar Chart
Authors:Sang-Ho Lee
Institution:Department of Industrial and Management Engineering, POSTECH , Pohang, South Korea
Abstract:A new control scheme is proposed by borrowing the idea of the Benjamini–Hochberg procedure for controlling the false discovery rate in multiple testing. It is shown theoretically that the proposed 2-span control scheme outperforms the Shewhart X-bar chart in terms of the average run length under any size of mean shifts. Some simulations are carried out to demonstrate that the proposed scheme having various span sizes always outperforms the X-bar chart in terms of the average run lengths.
Keywords:Average run length  Mean shift  Multiple testing  P-value  Quality control