首页 | 本学科首页   官方微博 | 高级检索  
     


Flow diagram analysis of electrical fatalities in construction industry
Authors:Chi Chia-Fen  Lin Yuan-Yuan  Ikhwan Mohamad
Affiliation:Department of Industrial Management, National Taiwan University of Science and Technology, 43 Sec 4, Keelung Rd, Taipei 106, Taiwan. chris@mail.ntust.edu.tw
Abstract:The current study reanalyzed 250 electrical fatalities in the construction industry from 1996 to 2002 into seven patterns based on source of electricity (power line, energized equipment, improperly installed or damaged equipment), direct contact or indirect contact through some source of injury (boom vehicle, metal bar or pipe, and other conductive material). Each fatality was coded in terms of age, company size, experience, performing tasks, source of injury, accident cause and hazard pattern. The Chi-square Automatic Interaction Detector (CHAID) was applied to the coded data of the fatal electrocution to find a subset of predictors that might derive meaningful classifications or accidents scenarios. A series of Flow Diagrams was constructed based on CHAID result to illustrate the flow of electricity travelling from electrical source to human body. Each of the flow diagrams can be directly linked with feasible prevention strategies by cutting the flow of electricity.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号